Product Details
Performance Index
Range code |
0D |
0C |
0B |
Measuring range |
-2.5kPa…-0.5kPa~0.5kPa…5kPa |
-10kPa…-1kPa~1kPa…10kPa |
0kPa~2kPa…20kPa |
Overpressure |
400kPa |
400kPa |
600kPa |
Power supply: 12V~28V DC (for intrinsically safe type, power supplied through guard grating)
Output signal: 4 mA~20 mA DC (two-wire system)
Load resistance: RL≤((U-12V)/0.02A)–Rw(Ω). Where: U --- supply voltage; Rw --- conductor resistance
Accuracy: ±0.5%FS (minimum) ±1.0%FS (typical value)
Temperature error: ≤±0.15%FS/10°C (-20°C~70°C)
≤±0.2%FS/10°C (-30°C~-20°C)
Long-term stability: ≤±0.5%FS/year
Vibration error: ≤±0.01%FS (X-,Y- and Z-axis, 200 Hz/g)
Ambient temperature: -30°C~70°C, -10°C~60°C (intrinsically safe type)
Medium temperature: -30°C~80°C
Storage temperature: -30°C~85°C
IP rating: IP65 (type I (universal type) and type II (cavity-free plug-in type)) IP68 (type III (cavity-free cable type III))
Interface and shell: stainless steel 1Cr18Ni9Ti
Sensor diaphragm: 96% alumina ceramic
Seal: fluororubber
Outline Structure
Electrical connection
Selection Guide
Notes for Selection
1. Please indicate the accuracy requirement in the purchase order while the selection is made; otherwise, the accuracy is considered as Class 1.0 for supply.
2. If option A (absolute pressure type) is selected, the minimum measuring range is [0~3]kPa and option N is not selected. If gauge pressure type is selected for negative pressure measurement, option N shall also be selected to indicate that it is allowed to measure negative pressure within the given minimum measuring range
http://www.youchurtsensor.com/